Shanghai Ditong Environmental Technology CO., LTD.

Hot Products
Contact us
Hotline
+86-021-62285701
+86-021-62285703
Address: First Floor, No. 34, Lane 329, Xinhua Road, Changning District, Shanghai, China
DPA classic type of suction arm - Explosion-proof Suspension
Auther: Pubdate:2020-06-18
DPA classic type of suction arm - Explosion-proof Suspension
 
Brand
 
 
Applied range
◆ The occasion for collecting dust pollution
◆ Collect welding dust pollution occasions
◆ The occasion of collecting oil fume pollution
◆ Capture volatile organic solvent gas pollution occasions
◆ The occasion for partial removal of hot air
◆ The occasion for partial air supply
 
Installation type
◆ The wall bracket shall be fixed for load bearing, and the shoulder hose socket shall be connected to the ventilation duct down the end, and an equipotential ground wire shall be connected.
 
Product superiority
◆ Scientific design and production of double four-side mechanism external bracket, high quality air pressure jacking bar balance gravity operation light hover reliable and durable.
◆ Equipped with adjustable anti-drift damping device to offset the pendulum effect caused by non-vertical mounting surface, convenient for mounting and reliable hover.
◆ Aluminum alloy surface epoxy resin powder spraying hard tube light weight and beautiful appearance, Europe's top brand steel reinforced conductive hose durable. 
◆ There is no obstruction in the whole pipe, and the ventilation volume is large with small wind resistance.
◆ Ratchet positioning air valve can adjust the air volume at will, and close the air valve when not in use to avoid waste of air volume, energy saving and environmental protection.
◆ The cyclone suction hood is light in weight and strong in rigidity.
◆ A reliable equipotential grounding device with a resistance of less than 1 ohm from the windshield to the equipotential grounding end of the shoulder.
 
Specification
 
Product Type Net Weight
(kg)
Nominal Diameter
(mm)
Extended Length
(m)
Cone Diameter
(mm)
Recommended Ventilation Rate (m3/h) Pressure Loss
(pa)
DPA-075-1.5-ATEX 4.5 75 1.5 175 100-250 140-500
DPA-075-2.0-ATEX 7.0 75 2.0 175 100-250 140-500
DPA-100-1.5-ATEX 5.0 100 1.5 200 300-500 250-860
DPA-100-2.0-ATEX 7.5 100 2.0 200 300-500 250-860
DPA-125-2-ATEX 9.8 125 2.0 265 400-700 300-940
DPA-125-3-ATEX 19.5 125 3.0 265 400-700 300-940
DPA-160-2-ATEX 18.5 160 2.0 300 800-1400 230-620
DPA-160-3-ATEX 22.5 160 3.0 300 800-1400 230-620
DPA-200-2-ATEX 21.3 200 2.0 340 1300-2200 280-820
DPA-200-3-ATEX 25.3 200 3.0 340 1300-2200 280-820
DPA-125-4-ATEX 23.0 125 4.0 265 400-700 300-940
DPA-160-4-ATEX 27.8 160 4.0 300 800-1400 230-620
DPA-200-4-ATEX 31.0 200 4.0 340 1300-2200 280-820